Automated dry-mist room disinfection with the airinspace HPVPA process: a hydrogen peroxide biocide boosted with peracetic acid that reaches every horizontal and vertical surface, with residue removal for fast turnover.

Overview

About RHEA

Manual cleaning may not reach every surface in a room, such as door handles, screens and light fittings. RHEA performs automated airborne surface disinfection (ASD): the room is closed, the device disperses the biocide as a dry mist and it reaches horizontal and vertical surfaces throughout the room. It is used for terminal disinfection, outbreak management and rooms previously occupied by patients with multidrug-resistant or highly contagious organisms.

The process dry-fogs X-CID, a 7.4% hydrogen peroxide biocide boosted with peracetic acid, which spreads evenly through the room, condenses as micro-droplets on every surface and destroys micro-organisms by oxidation. airinspace has the process assessed to EN 17272:2020, with log reductions of 5 for bacteria (Acinetobacter baumannii, E. coli, Staphylococcus aureus, Enterococcus hirae) and 4 for fungi and yeasts (Candida albicans, Aspergillus brasiliensis), spores (Bacillus subtilis), mycobacteria (M. terrae, M. avium) and viruses (adenovirus, norovirus). Each cycle has three steps: diffusion, contact and ventilation. In a 50 m³ patient room with the virus protocol (6 ml/m³), airinspace gives 14 minutes of diffusion, 60 minutes of contact and 45 minutes of ventilation with eCHEM Cubair, about 2 hours in total. A DSVA detector confirms hydrogen peroxide is at a safe level before the room is reopened.

Key features

  • Dry fogging of X-CID: 7.4% hydrogen peroxide boosted with peracetic acid
  • EN 17272:2020: log 5 bacteria; log 4 fungi, spores, mycobacteria and viruses
  • RHEA One: 6.2 kg, 2.5 L X-CID can in the housing, 17–21 ml/min diffusion, USB traceability, remote control
  • RHEA Compact: touch screen with pre-programmed protocols; trolley with eCHEM Cubair
  • RHEA Titan: high capacity, two X-CID bottles, NFC records, built-in printer
  • eCHEM Cubair (CUBAIR OX): H₂O₂ removal up to 2,400 m³/h with boost mode
  • DSVA detector for residual hydrogen peroxide

Models

Photos and models

RHEA One

RHEA One

Portable dry fogger, 6.2 kg

RHEA Compact trolley

RHEA Compact trolley

RHEA Compact with eCHEM Cubair on one trolley

eCHEM Cubair (CUBAIR OX)

eCHEM Cubair (CUBAIR OX)

Removes H₂O₂ residues up to 2,400 m³/h

X-CID HPV 2.5 L

X-CID HPV 2.5 L

Ready-to-use biocide

X-CID HPV 1 L

X-CID HPV 1 L

Ready-to-use biocide

Hydrogen peroxide detector

Hydrogen peroxide detector

Confirms safe H₂O₂ levels before re-entry

Where it is used

  • Terminal disinfection after discharge
  • Multidrug-resistant bacteria (VRE, MRSA) and outbreaks (C. difficile, Acinetobacter, Klebsiella, norovirus)
  • Aspergillus control during construction
  • BSL-2 and BSL-3 laboratories, microbiology and cell-culture labs
  • Patient rooms and clean rooms before return to service

What Capnova provides

  • Site assessment and sizing for each room
  • Supply, installation and commissioning
  • Training for clinical, cleaning and biomedical teams
  • Preventive maintenance and after-sales service
  • Protocols aligned with CDC guidance

RHEA technical data

From the manufacturer's published information. Capnova confirms the current configuration and local registration status before every proposal.

Process
HPVPA airborne surface disinfection by dry fogging
Biocide
X-CID HPV: ready-to-use, non-corrosive, low-concentration hydrogen peroxide (7.4%) boosted with peracetic acid; 1 L and 2.5 L bottles; 2-year shelf life, use within 4 months of opening; EU BPR 528/2012
Standard
Assessed to EN 17272:2020: bactericidal log 5; fungicidal, yeasticidal, sporicidal, mycobactericidal and virucidal log 4
Cycle example
50 m³ room, virus protocol 6 ml/m³: 14 min diffusion, 60 min contact, 45 min ventilation
RHEA One
6.2 kg; 17 × 32 cm; diffusion 17–21 ml/min; USB traceability; remote control
RHEA Titan
64 × 55 × 114.5 cm; two X-CID bottles; NFC records; built-in printer
eCHEM Cubair (CUBAIR OX)
H₂O₂ adsorption up to 2,400 m³/h; boost mode; driven by RHEA or remote control
DSVA
Portable detector for residual hydrogen peroxide
Safety
Run in an unoccupied room; re-enter when residual H₂O₂ is at or below the exposure limit (usually 1 ppm), checked with a detector

Questions

Common questions about RHEA

We supply, install and support it for hospitals and clinics in the UAE (Dubai, Abu Dhabi, Sharjah), Saudi Arabia (Riyadh, Jeddah, Dammam), Qatar, Kuwait, Oman, Bahrain and Egypt.

What is airborne surface disinfection?

Airborne surface disinfection (ASD) disperses a biocide into a closed room so it reaches every horizontal and vertical surface, including those missed by manual cleaning. RHEA uses airinspace's HPVPA process with X-CID, a hydrogen peroxide biocide boosted with peracetic acid.

What is X-CID HPV?

X-CID HPV is airinspace's ready-to-use, non-corrosive biocide for RHEA dry foggers: a low concentration of hydrogen peroxide boosted with peracetic acid, validated with RHEA to EN 17272:2020. It comes in 1 L and 2.5 L bottles, keeps for two years and should be used within four months of opening.

How long does RHEA room disinfection take?

It depends on the room volume and protocol. airinspace's example for a 50 m³ patient room with the virus protocol is 14 minutes of diffusion, 60 minutes of contact and 45 minutes of ventilation with eCHEM Cubair, about 2 hours in total. A DSVA detector confirms safe hydrogen peroxide levels before re-entry.

How do RHEA and UV disinfection work together?

UV-C devices such as THOR disinfect surfaces in a fast, chemical-free cycle; RHEA disperses a biocide that reaches every surface of a closed room. Hospitals use RHEA for outbreaks and multidrug-resistant organisms and UV-C for routine terminal disinfection.

How much does a RHEA room disinfection system cost?

Price depends on the model (RHEA One, Compact or Titan), the room volumes and the X-CID consumption. Capnova sends a quotation after reviewing your rooms.

Related

Works well with

Get a quote for RHEA