← Products & brands

airinspace, France

PLASMAIR plasma air decontamination unit (H14–U15)

Mobile units that destroy airborne microorganisms with HEPA-MD® cold-plasma technology and capture fine particles, for haematology, transplant, ICU, theatres and burns.

PLASMAIR Guardian mobile air decontamination unit

At a glance

Mobile medical air decontamination · airinspace, France

For severely immunosuppressed patients, airborne fungal spores such as Aspergillus are a serious threat, especially during nearby construction or renovation. PLASMAIR units bring high-level air treatment to a room without building works.

  • HEPA-MD® cold-plasma decontamination with H14–U15 filtration
  • PLASMAIR Guardian: up to 2,500 m³/h
  • PLASMAIR Sentinel: up to 1,200 m³/h, the quietest HEPA-MD® unit
  • Touch-screen control, mobile on wheels

Models

Photos and models

PLASMAIR Guardian

PLASMAIR Guardian

Up to 2,500 m³/h, H14–U15

PLASMAIR Sentinel

PLASMAIR Sentinel

Up to 1,200 m³/h, the quietest HEPA-MD® unit

PLASMAIR Satellite

PLASMAIR Satellite

Ceiling-mounted, up to 1,200 m³/h

Overview

Two models cover most needs: PLASMAIR Guardian for high flow in larger rooms and theatres, and PLASMAIR Sentinel, a smaller, quieter unit for patient rooms and NICU-type settings.

Technology

airinspace's patented HEPA-MD® reactor combines non-thermal (cold) plasma, which destroys microorganisms, with electrically active collection media and a medical HEPA filter for very high particle efficiency. The units also retain volatile organic compounds and odours, and airinspace states they release no toxic by-products and create no formaldehyde.

airinspace reports that the effectiveness of HEPA-MD® has been demonstrated by independent institutions including CNRS and the Harvard School of Public Health. Both units connect to IMMUNAIR® and BIOCAIR® to create protected environments.

Applications

  • Haematology and onco-haematology
  • Bone marrow and solid organ transplant units
  • Intensive care
  • Operating rooms
  • Burns units
  • Hospital pharmacy and cytotoxic preparation areas

Key features

  • HEPA-MD® cold-plasma decontamination with H14–U15 filtration
  • PLASMAIR Guardian: up to 2,500 m³/h
  • PLASMAIR Sentinel: up to 1,200 m³/h, the quietest HEPA-MD® unit
  • Touch-screen control, mobile on wheels
  • Connects to IMMUNAIR® and BIOCAIR® protected environments
PLASMAIR Sentinel compact air decontamination unit

Technical data

PLASMAIR technical specifications

From the manufacturer's published information. Capnova confirms the current configuration and local registration status before every proposal.

TechnologyHEPA-MD®: non-thermal plasma plus electrically active collection media and medical HEPA filterairinspace
PLASMAIR Guardian flowUp to 2,500 m³/hairinspace
PLASMAIR Guardian filterH14 – U15airinspace
PLASMAIR Guardian dimensionsH 194 cm × L 91.2 cm × D 69 cmairinspace
PLASMAIR Sentinel flowUp to 1,200 m³/hairinspace
PLASMAIR Sentinel filterH14 – U15; ULPA filter with 25 m² filtering areaairinspace
PLASMAIR Sentinel dimensionsH 151 cm × L 75 cm × D 52 cmairinspace
Standards citedISO 9001 (company); acoustic measurement to ISO 3744:2012airinspace
HEPA-MD® stages1 microbial destruction by non-thermal plasma; 2 biological and particulate arrestance; 3 catalytic conversion of ozone and NOx; 4 molecular trapping on activated carbonairinspace
PLASMAIR SatelliteCeiling-mounted, no floor space, remote control; up to 1,200 m³/h; for ISO 7 / ISO 8 high-risk areasairinspace
Sizing example60 m³ room × 20 air changes per hour = 1,200 m³/h → PLASMAIR Sentinel; reduces ISO 9 to ISO 7 / ISO 6 within minutesairinspace
Power, weight, noise levelsAvailable on request

CDC guidelines

Applications and recommendations for PLASMAIR

CDC recommendations are product-neutral. Each row shows the CDC recommendation for the application and how the device helps put it into practice, as an additional layer alongside ventilation, manual cleaning, hand hygiene and reprocessing.

ApplicationCDC recommendationHow PLASMAIR supports it
Protective environment rooms (e.g. allogeneic HSCT recipients)Provide HEPA-filtered supply air, positive pressure relative to the corridor and at least 12 air changes per hour in well-sealed rooms.CDC Guidelines for Environmental Infection ControlPoint-of-use HEPA-MD® treatment (H14–U15) that complements the room's protective-environment ventilation.
Construction and renovation near immunocompromised patientsPerform an infection-control risk assessment (ICRA) and protect severely immunocompromised patients from Aspergillus and other airborne fungi; portable HEPA units may supplement.CDC Guidelines for Environmental Infection ControlMobile units deployed in patient rooms during works.
Airborne infection isolation roomsPortable HEPA recirculation units can augment removal of respirable particles.CDC Guidelines for Environmental Infection ControlAdds filtered, decontaminated air changes inside the room.
Operating roomsMaintain positive pressure, at least 15 air changes per hour (at least 3 of fresh air) and appropriate filtration.CDC Guidelines for Environmental Infection ControlSupplementary point-of-use air treatment for high-risk surgery.

See also: facility scenarios and UVC chamber compatibility list.

CDC references

  1. CDC/HICPAC. Guidelines for Environmental Infection Control in Health-Care Facilities. MMWR 2003;52(RR-10), updated 2019. Source

Certifications & evidence

  • airinspace holds ISO 9001 certification. The PLASMAIR Guardian user manual states CE marking under the European Low Voltage and Electromagnetic Compatibility directives.
  • Fernandez-Gerlinger MP, et al. The Plasmair decontamination system is protective against invasive aspergillosis in neutropenic patients. Infection Control & Hospital Epidemiology. 2016;37(7):845–851. A retrospective cohort of 156 patients in a haematology intensive care unit.

Documents & downloads

Where PLASMAIR is used

See how PLASMAIR fits with other technologies in each department.

Read: Clean air for high-risk patients: HEPA, cold plasma and protected environments →

Questions

Common questions about PLASMAIR hospital air decontamination unit

We supply, install and support it for hospitals and clinics in the UAE (Dubai, Abu Dhabi, Sharjah), Saudi Arabia (Riyadh, Jeddah, Dammam), Qatar, Kuwait, Oman, Bahrain and Egypt.

How do I size a PLASMAIR unit for a room?

Multiply the room volume by the target air changes per hour. airinspace's example: a 60 m³ room at 20 air changes per hour needs 1,200 m³/h, which is one PLASMAIR Sentinel, bringing the room from ISO 9 to ISO 7 or ISO 6 within minutes.

Does airinspace have a ceiling-mounted plasma air purifier?

Yes. PLASMAIR Satellite is a compact, ceiling-mounted unit with the HEPA-MD® reactor, H14 HEPA filtration and activated carbon, at up to 1,200 m³/h, for rooms where floor space is limited.

Can PLASMAIR Guardian create negative or positive pressure in a room?

Yes. PLASMAIR Guardian connected to a room creates positive or negative pressure, including in BIOCAIR® isolation rooms. With Wall-i Pilot the flow rate is adjusted automatically to hold the set pressure.

How much does a medical air purifier cost?

Price depends on the model (PLASMAIR Guardian, Sentinel or Satellite) and the number of units your rooms need. Send us the room sizes and Capnova will return a quotation.

What is a plasma air purifier for hospitals?

PLASMAIR uses airinspace's patented HEPA-MD® reactor: non-thermal (cold) plasma destroys airborne microorganisms, then electrically active collection media and a medical HEPA filter (H14–U15) capture fine particles. It is a mobile medical air decontamination unit on wheels.

What is the best air purifier for hospitals?

For immunosuppressed patients, hospitals use medical-grade air decontamination rather than consumer purifiers. PLASMAIR combines airinspace's patented HEPA-MD® cold-plasma reactor with H14–U15 filtration, and is mobile so it can be moved to the rooms that need it.

How does PLASMAIR protect against Aspergillus?

Airborne fungal spores such as Aspergillus are a serious threat to severely immunosuppressed patients, especially during construction. PLASMAIR destroys airborne microorganisms with cold plasma and captures fine particles, without building works.

Which PLASMAIR model do I need?

PLASMAIR Guardian delivers up to 2,500 m³/h for larger rooms and theatres. PLASMAIR Sentinel delivers up to 1,200 m³/h and is the quietest HEPA-MD® unit, for patient rooms and NICU-type settings. Capnova sizes units from room volume and target air changes.

Is PLASMAIR available in the UAE and Saudi Arabia?

Yes. Capnova Medical Solutions supplies airinspace PLASMAIR with assessment, installation and support across the UAE, Saudi Arabia, Qatar, Kuwait, Oman, Bahrain and Egypt.

Get a quote for PLASMAIR

Tell us about your facility and we will recommend the right quantity and configuration.